Skip to content

SCR DeNOx: The Complete Guide

Direct answer: Selective Catalytic Reduction (SCR) removes NOx from flue gas by reacting it with ammonia over a V-Mo-Ti (vanadium-based) catalyst, converting NOx to nitrogen and water. It is the workhorse NOx control technology for coal power, steel, cement, glass and waste incineration — typically delivering 80–95% NOx removal within a defined temperature window. This guide is the hub: it summarizes the whole SCR topic and links to detailed articles on every part of it.

Key Engineering Point: SCR performance is set by the temperature window and the flue-gas condition at the catalyst face — dust, SO₂ and alkali metals degrade activity faster than age does. A catalyst chosen on removal rate alone fails if the inlet conditions are wrong.

Material entity profile

Entity field SCR DeNOx catalyst
Material class Heterogeneous reduction catalyst
Composition V₂O₅ (active) / MoO₃ or WO₃ (promoter) / TiO₂ (support); plate catalysts on steel mesh, honeycomb as extruded monolith
Structure Macroporous monolith channels (pitch ~6–9 mm plate; 6–20 cells honeycomb)
Key properties NOx conversion, SO₂→SO₃ oxidation rate, ammonia slip, pressure drop, erosion resistance
Target pollutants NOx (NO + NO₂)
Mechanism NH₃ + NOx → N₂ + H₂O over active sites
Regeneration Chemical cleaning / rejuvenation in place or ex situ

Data type: operating windows and design ranges are Typical Value engineering references; product data are Manufacturer Specification. See Data Classification and the Evidence Registry.


1. What SCR does and where it is used

SCR converts nitrogen oxides (NO and NO₂, together NOx) into harmless N₂ and water using ammonia as the reducing agent:

4NO + 4NH₃ + O₂ → 4N₂ + 6H₂O

The catalyst makes this reaction proceed at 200–420°C instead of the ~900°C that uncatalyzed thermal reduction would need. Applications:

Industry Typical duty
Coal-fired power NOx compliance on high-dust flue gas
Steel & sintering Sinter machine exhaust NOx
Cement Kiln exhaust with high alkali dust
Glass & ceramics High-temperature furnace NOx
Waste incineration Municipal and hazardous waste flue gas
Chemical & refining Tail gas and process vents

2. How the catalyst works

The catalyst is titanium dioxide (TiO₂) support carrying vanadium pentoxide (V₂O₅) as the active component and tungsten or molybdenum trioxide (WO₃/MoO₃) as promoters that widen the temperature window and suppress SO₂ oxidation.

  • Standard SCR: NO dominates; 4NO + 4NH₃ + O₂ → 4N₂ + 6H₂O.
  • Fast SCR: NO₂ present accelerates the reaction at lower temperature.
  • Side reaction to control: SO₂ oxidation to SO₃ (target ≤1%) and NH₃ oxidation at high temperature.

Ammonia is injected upstream — in coal power as anhydrous NH₃, aqueous ammonia or urea (decomposed to NH₃) — and mixed across the duct by an ammonia injection grid (AIG).

3. Catalyst types: plate vs honeycomb

Two geometries dominate. Details in Plate vs Honeycomb.

  • Plate-type: metal mesh support with rolled catalyst paste — open channels, high erosion tolerance, the standard choice for high-dust coal flue gas.
  • Honeycomb: extruded homogeneous catalyst — higher specific activity per volume, preferred where dust is moderate and volume is constrained.

Both are modular: elements are assembled into steel frames (modules) stacked in the reactor, typically 2+1 or 3+1 layers with a spare layer position.

4. Key design parameters

Parameter Typical range Notes
Operating temperature 200–420°C Below window: low activity + bisulfate; above: NH₃ oxidation
Space velocity (SV) 2,000–8,000 h⁻¹ Depends on gas conditions and required conversion
Face velocity 4–6 m/s Balances pressure drop and erosion
Channel pitch ~6–9 mm (plate), 6–20 cells (honeycomb) Larger pitch for high dust
NH₃/NOx molar ratio 0.8–1.05 Above 1: rising ammonia slip
SO₂ oxidation rate ≤1% Formulation-dependent; SO₃ drives bisulfate issues
Design NOx removal 80–95% Set by permit and economic trade-off

Data type: Typical Value engineering references for design guidance — not product specifications and not universal guarantees. Product-specific values are Manufacturer Specification; see Data Classification.

The selection decision path is covered step-by-step in the articles below — the short version: define gas conditions (temperature, NOx, SO₂, dust, moisture), choose geometry, size volume with deactivation margin, then verify with simulation testing on the actual gas.

5. Operation: the three watched numbers

SCR health is monitored through three trends, always together:

  1. NOx conversion at a fixed reference load and temperature.
  2. NH₃ slip — the early warning of active-site loss.
  3. Pressure drop — the signal for plugging and mechanical issues.

The details of controlling ammonia distribution, slip and flow conditioning are in Ammonia Slip Control.

6. Deactivation: how catalysts die

Mode Mechanism Reversible? Article
Arsenic poisoning As₂O₃ vapor blocks pores Mostly no Poisoning
Alkali (K, Na) poisoning Neutralizes acid sites Partially (washing) Poisoning
Ammonium bisulfate SO₃ + NH₃ deposit below ~280–320°C Yes (thermal/cleaning) Poisoning
Ash plugging & erosion Mechanical damage Cleaning helps; erosion is terminal Ash & Erosion
Thermal sintering High-temperature structure loss No Replacement

When performance falls, the decision between regeneration and replacement follows a measured sequence — Regeneration and Replacement cover both paths.

7. Performance verification

Catalyst activity is quantified as the activity K (m/h), derived from conversion at defined space velocity. Verification runs in three tiers: laboratory characterization, simulation with the real gas, and in-situ field testing — Activity Testing - Low-Temperature SCR — 160–250°C operation, ABS control, formulation choices. - Reactor Positioning — high-dust, low-dust and tail-end layouts. - Reducing Agent Systems — anhydrous ammonia, aqueous ammonia, urea. - Catalyst Volume Calculation — K, area velocity, layer management. - Flow Distribution & CFD - SNCR vs SCR — choosing the DeNOx route, hybrids, cost curves. - Cleaning & Maintenance — sootblowing, ΔP monitoring, inspection. — uniformity, AIG tuning, field verification..

8. Quick reference: symptom → cause

Symptom Most likely cause Go to
Conversion falls, slip rises Chemical deactivation Poisoning
Conversion falls, ΔP rises Plugging / ash Ash & Erosion
Slip high, conversion fine AIG imbalance or over-injection Ammonia Slip
Performance falls after cleaning only slightly recovers Irreversible poisoning Regeneration
ΔP doubled since commissioning Channel erosion/plugging Replacement

9. The complete SCR article series

When SCR is not the right choice

  • Flue gas temperature far below the catalyst window with no reheating budget — evaluate SNCR, staging or a low-temperature formulation after a bisulfate audit.
  • Very high SO₃ with no upstream control — catalyst poisoning and acid condensation dominate economics.
  • Unknown fuel/poison profile with no test program — see Catalyst Selection for the full decision path.
  • Space or pressure-drop constraints no catalyst geometry can satisfy.

10. Manufacturer perspective

SCR is a systems problem, not a catalyst purchase. The same NOx target can require 20–40% more catalyst volume on a high-poisoning fuel, and even the best catalyst behind a badly tuned AIG will slip ammonia from day one. We size from the current fuel and flue gas analysis, the measured velocity distribution and the outage window — and we recommend simulation testing with your actual gas before large orders.