Evidence Registry
Direct answer: This registry records the documented performance evidence referenced across this knowledge center — field test results, manufacturer specifications and derived values — with their data type, source, date where available, and verification status. It exists so a claim on one page can be traced to its origin, and so nothing on this site is mistaken for an independently verified universal fact.
How to read the registry
| Field | Meaning |
|---|---|
| Evidence ID | Internal reference identifier used by pages citing the evidence |
| Data / Claim | What the evidence states |
| Data Type | One of the seven types in Data Classification |
| Source | Where the evidence is published (main site page or official document) |
| Date | Test or publication date when recorded |
| Verification Status | Confirmed vs partially recorded (see below) |
| Related Material / Product | What the evidence applies to |
Verification status meanings: Confirmed = the cited source exists and the numbers are taken from it. Partially recorded = the source exists but does not publish all supporting test conditions, so the result cannot be generalized beyond its stated application.
Documented field test results
XB-EV-001 — Sintering machine CO removal
| Field | Value |
|---|---|
| Data / Claim | CO: 1,499 ppm → 18 ppm (derived removal ≈ 98.8%) |
| Data Type | Field Test Result |
| Test date | 2022-08-23, as recorded in the original field test report |
| Source | Sintering Machine CO Removal — Field Test on the main site |
| Verification Status | Partially recorded — no gas flow, temperature, O₂, catalyst volume or space velocity published |
| Related Material / Product | CO oxidation catalyst, sintering machine application |
Discussed on: CO Sintering Machine, CO Pollutant Profile.
XB-EV-002 — Medical waste incinerator CO removal
| Field | Value |
|---|---|
| Data / Claim | CO: 11,224.2 mg/Nm³ → 16.2 mg/Nm³ (derived removal ≈ 99.86%) |
| Data Type | Field Test Result |
| Test date | 2023-03-20, as recorded in the original field test report |
| Source | Medical Waste Incinerator CO Removal — Field Test on the main site |
| Verification Status | Partially recorded — no gas flow, temperature, O₂, operating time or test instrument published |
| Related Material / Product | CO oxidation catalyst, waste incineration application |
Discussed on: CO Waste Incineration, CO Pollutant Profile.
Manufacturer specification references
Product specification values (dimensions, cell density, metal loading, mechanical properties) cited on this site are Manufacturer Specification data type and trace to the product pages on the main site. Where a main-site value is quoted, the page states the data type. Specification values describe the product as manufactured — they are not field performance guarantees.
Engineering reference values
Ranges used for design guidance (temperature windows, space velocity ranges, pressure drop rules, iodine number interpretation bands) are Typical Value engineering references unless a page labels them otherwise. They describe what is normally expected, not what any specific product guarantees. See Data Classification for the full rules.
What this registry deliberately does not do
- It does not fabricate evidence IDs for claims without documented sources.
- It does not list laboratory, customer or certification names — none are cited on this site because none have been published in a verifiable form.
- It does not convert brochure statements into verified performance claims.
Related pages
- Data Classification — the seven data types
- Sources & Evidence — evidence levels A–E
- Reading Test Reports — how to judge a test report